300-615 無料問題集「Cisco Troubleshooting Cisco Data Center Infrastructure」

Refer to the exhibit. An engineer fails to implement a Cisco UCS Manager integration manager.
The credentials and IP connectivity between Cisco APIC and UCS Manager are configured as expected. Which action resolves the issue?

Which Cisco NX-OS command can be used to determine if OSPF hello packets are being transmitted and received between neighbors?

解説: (JPNTest メンバーにのみ表示されます)
Refer to the exhibit. After an unexpected reload of the Cisco Nexus 9000 Series Switch, the network administrator noticed that one of the Software Maintenance Upgrades (SMU) images is inactive.
The engineer must ensure that the package remains active after the switch is reloaded in the future. Which action accomplishes this goal?

An engineer is troubleshooting a packet flow from an access leaf to spine. Which EVPN routes are expected on this connection?

Refer to the exhibit. You configure an MTU on an Ethernet port profile.
Where is the MTU value unsupported?

解説: (JPNTest メンバーにのみ表示されます)
A server administrator attempts to change the Cisco IMC KVM certificate to one signed by a private CA, but the certificate is not being accepted. What can cause this process to fail?

Refer to the exhibit. A Cisco UCS system fails to access the storage array. Which two actions taken on both MDS switches resolve the issue? (Choose two.)

正解:A、E 解答を投票する
Refer to the exhibit. After a failover occurs, which two actions must be performed on Switch-B to manually preempt the operational primary role back to Switch-A? (Choose two.)

正解:B、D 解答を投票する
Refer to the exhibit. An attempt to bind the Ethernet interface to vFC fails.
Which action resolves the issue?

解説: (JPNTest メンバーにのみ表示されます)
Refer to the exhibit. A network engineer configures OSPF protocol between two Cisco Nexus
7000 Series Switches. The OSPF neighbors fail to synchronize OSPF databases. Which action resolves the issue?

A network administrator adds several Cisco UCS C-Series servers to the existing Cisco UCS environment. Some of the servers fail to be discovered in Cisco UCS Manager. Which two actions resolve the issue? (Choose two.)

正解:B、D 解答を投票する
Refer to the exhibit. A client is reporting packet drops destined for the call recording server connected to Cisco Nexus 9000 Series Switch. Which action resolves the issue?

Refer to the exhibit. The scheduled Test job fails to be reconfigured with extra configuration on Cisco 9000 Series Switch. Which action resolves the issue?

You have an ACI environment with three APICs, two spine switches, and four-leaf switches. You wipe and reboot all APICs first then leaf and spine switches one- by-one and successfully go through the Initial Setuo dialogue on the APIC 1 CIMC KVM console. When you log in to the APIC1 WebGUI, you notice that you do not see any directly connected leaf switches being discovered under Fabric > Inventory > Fabric Membership. What is the cause of the issue?

解説: (JPNTest メンバーにのみ表示されます)
Refer to the exhibit. A newly deployed Cisco APIC1 fails to discover a Cisco Nexus Series Switch. Which configuration resolves the issue?

Refer to the exhibit. A network engineer must display the status of the vPC domain using the Python script and guest shell. The status of Cisco Nexus switches 1 and 2 must be displayed, but the code fails and displays the status of Cisco Nexus switches 0 and 1 instead. Which code resolves the issue?