During the early stages of a LEED for Schools project, the team was able to reduce the number of lighting fixtures in classrooms by 25% because the project team selected paint color whose light reflectance value was
75% instead of the initially proposed 64% value. This strategy is an example of applying which of the following credits to the project?
75% instead of the initially proposed 64% value. This strategy is an example of applying which of the following credits to the project?
正解:D
解答を投票する
解説: (JPNTest メンバーにのみ表示されます)
A project team member has prepared a map and accompanying table as documentation for the Location and Transportation Credit. Surrounding Density and Diverse Uses. Option 2. Diverse Uses. The map includes the location of each diverse use. the location of the project and the main entrance of the building. The table includes the distance to each use. the name of each use and the category of each use The team lead reviews the documentation and notes an important missing item. Which of the following is the most important item to add to the documentation?
正解:C
解答を投票する
解説: (JPNTest メンバーにのみ表示されます)
In order to meet the minimum qualifications for Energy and Atmosphere Prerequisite, Fundamental Commissioning and Verification a Commissioning (Cx) agent must have completed the commissioning process activities for a minimum of how many similar projects?
正解:D
解答を投票する
解説: (JPNTest メンバーにのみ表示されます)
An urban office building project is installing a cooling tower. To save on potable water, the project would like to use a nonpotable water source to provide 20% of the cooling tower makeup water to achieve the maximum number of points under Water Efficiency Credit, Cooling Tower Water Use. Which nonpotable water source would be the most appropriate for use?
正解:A
解答を投票する
解説: (JPNTest メンバーにのみ表示されます)
Several Materials and Resources credits give a bonus location valuation factor, which allows products extracted, manufactured and produced within 100 mi. (161 km) of the project to take double valuation in credit calculations. The intent of this bonus is
正解:C
解答を投票する
解説: (JPNTest メンバーにのみ表示されます)
The design team is attempting to achieve the Increased Ventilation strategy in the Indoor Environmental Quality Credit, Enhanced Indoor Air Quality in a conference room. The associated ASHRAE standard requires 400 CFM (11.3 CMM) of ventilation air, but the local code requires 500 CFM (14.1 CMM) of ventilation air. What is the required minimum amount of ventilation air to achieve this credit?
正解:D
解答を投票する
解説: (JPNTest メンバーにのみ表示されます)