質問 # 69
Electrical power (P) is measured in ___________?

  • A. henries
  • B. Ohms
  • C. Watts
  • D. Farads

正解:C


質問 # 70
Which of the following interconnects the PBB to the SBB?

  • A. TBB
  • B. BBC
  • C. RBB
  • D. TEBC

正解:A


質問 # 71
Which of the following is used to perform continuity and length tests for coaxial cable?

  • A. OTDR (optical time domain reflectometer
  • B. VFL (visual fault locator)
  • C. TDR (Time domain reflectometer) with an adapter
  • D. OLTS (optical loss test set)

正解:C


質問 # 72
Which of the following is the MAIN reason for staggering splice closures or consolidation points in a backbone pathway?

  • A. To optimize pulling tension at multiple intervals
  • B. To reduce electromagnetic interference in the fiber
  • C. To ensure compliance with local electrical codes
  • D. To allow adequate space for service loops and reduce congestion

正解:D


質問 # 73
Which of the following is used to measure the length of a 4-pair cable?

  • A. Pair scanner
  • B. Time domain reflectometer (TDR)
  • C. Tone generator
  • D. Cable-end locator kit

正解:B


質問 # 74
What is the characteristic impedance of Series-6 coaxial cable?

  • A. 100 ohms
  • B. 75 ohms
  • C. 50 ohms
  • D. 25 ohms

正解:B


質問 # 75
Which of the following tools is a low-cost cable verifier that can be used to test for opens, shorts, crossed pairs, and miswires in 4- pair cables?

  • A. Wire map tester
  • B. Telephone test set
  • C. TDR
  • D. Qualification tester

正解:A


質問 # 76
What is the bend radius requirement for optical fiber cable when the cable is at rest?

  • A. 15 times the cables outside diameter
  • B. 20 times the cables outside diameter
  • C. 10 times the cables outside diameter

正解:C


質問 # 77
Which of the following is the bonding connection point for telecommunications systems and equipment in the area by a telecommunication space?

  • A. SBB
  • B. BBC
  • C. RBB
  • D. TEBC

正解:A


質問 # 78
A category 8 cable is terminated into category 6A outlets with category 5e patch cords. What is the maximum supported performance level?

  • A. Category 8
  • B. Category 5e
  • C. Category 7
  • D. Category 6A

正解:B


質問 # 79
How far should the top of a ladder extend above the roofline?

  • A. 0.6 m (2')
  • B. 0.3 m (1')
  • C. 0.9 m (3')
  • D. 0.5 m (1.6')

正解:C


質問 # 80
What is the markings for non-conductive optical fiber riser cable?

  • A. OFNG
  • B. OFCR
  • C. OFNR
  • D. OFNP

正解:C


質問 # 81
Which of the following fire ratings refers to the time period that a fire-rated assembly can resist flame passage?

  • A. W rating
  • B. T rating
  • C. F rating
  • D. L rating

正解:C


質問 # 82
What is the minimum recommended height that should be used when mounting a plywood back board in a telecommunication space?

  • A. AFF 200 mm (8")
  • B. AFF 150 mm (6")
  • C. 100 mm (4")
  • D. AFF 300 mm (12") AFF

正解:A


質問 # 83
Which of the following is a floor serving space that serves as a point of termination for horizontal and backbone cables?

  • A. EF
  • B. ER
  • C. TR
  • D. TE

正解:C


質問 # 84
Which of the following is designed to provide protection from harmful chemicals?

  • A. Leather gloves
  • B. Rubber gloves
  • C. Cut-resistant gloves

正解:B


質問 # 85
What is the minimum recommended amount of vertical clearance for open-top cable supports?

  • A. 150 mm (6")
  • B. 100 mm (4")
  • C. 75 mm (3")
  • D. 125 mm (5")

正解:C


質問 # 86
How much sheath of the cable needs to be removed in order to properly terminate an 8P8C?

  • A. 25mm (1")
  • B. 38 mm (1.5")
  • C. 12.7mm (0.5")
  • D. 6.3mm (0.25")

正解:C


質問 # 87
What is the primary difference between an Equipment Rack and a Cabinet, as referenced in BICSI documentation?

  • A. A rack provides open mounting rails, whereas a cabinet has doors or side panels for equipment protection
  • B. A cabinet requires no grounding or bonding, whereas a rack must be grounded
  • C. An equipment rack is used for fiber while a cabinet is used for copper only
  • D. Cabinets can only be installed on exterior walls, while racks are installed in the room interior

正解:A


質問 # 88
The information transmitted by an ICT system can originate in two fundamental forms:

  • A. Synchronous and asynchronous
  • B. Progressive and regressive
  • C. Analog and digital
  • D. Light and sound

正解:C


質問 # 89
What is the minimum number of consolidation points that should serve an open office furniture cluster?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:D


質問 # 90
Which of the following is a property of an electromagnetic field built around a conductor that opposes any changes in current flow in a circuit?

  • A. Impedance
  • B. Capacitance
  • C. Resistance
  • D. Inductance

正解:D


質問 # 91
The horizontal distance from the base of the ladder to the supporting wall should be ____ percent the working length of the ladder.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:A


質問 # 92
Which of the following is used to express system gain and loss?

  • A. Decibel (dB)
  • B. Ohms
  • C. Henries
  • D. Farads

正解:A


質問 # 93
......