質問 # 69
Electrical power (P) is measured in ___________?
- A. henries
- B. Ohms
- C. Watts
- D. Farads
正解:C
質問 # 70
Which of the following interconnects the PBB to the SBB?
- A. TBB
- B. BBC
- C. RBB
- D. TEBC
正解:A
質問 # 71
Which of the following is used to perform continuity and length tests for coaxial cable?
- A. OTDR (optical time domain reflectometer
- B. VFL (visual fault locator)
- C. TDR (Time domain reflectometer) with an adapter
- D. OLTS (optical loss test set)
正解:C
質問 # 72
Which of the following is the MAIN reason for staggering splice closures or consolidation points in a backbone pathway?
- A. To optimize pulling tension at multiple intervals
- B. To reduce electromagnetic interference in the fiber
- C. To ensure compliance with local electrical codes
- D. To allow adequate space for service loops and reduce congestion
正解:D
質問 # 73
Which of the following is used to measure the length of a 4-pair cable?
- A. Pair scanner
- B. Time domain reflectometer (TDR)
- C. Tone generator
- D. Cable-end locator kit
正解:B
質問 # 74
What is the characteristic impedance of Series-6 coaxial cable?
- A. 100 ohms
- B. 75 ohms
- C. 50 ohms
- D. 25 ohms
正解:B
質問 # 75
Which of the following tools is a low-cost cable verifier that can be used to test for opens, shorts, crossed pairs, and miswires in 4- pair cables?
- A. Wire map tester
- B. Telephone test set
- C. TDR
- D. Qualification tester
正解:A
質問 # 76
What is the bend radius requirement for optical fiber cable when the cable is at rest?
- A. 15 times the cables outside diameter
- B. 20 times the cables outside diameter
- C. 10 times the cables outside diameter
正解:C
質問 # 77
Which of the following is the bonding connection point for telecommunications systems and equipment in the area by a telecommunication space?
- A. SBB
- B. BBC
- C. RBB
- D. TEBC
正解:A
質問 # 78
A category 8 cable is terminated into category 6A outlets with category 5e patch cords. What is the maximum supported performance level?
- A. Category 8
- B. Category 5e
- C. Category 7
- D. Category 6A
正解:B
質問 # 79
How far should the top of a ladder extend above the roofline?
- A. 0.6 m (2')
- B. 0.3 m (1')
- C. 0.9 m (3')
- D. 0.5 m (1.6')
正解:C
質問 # 80
What is the markings for non-conductive optical fiber riser cable?
- A. OFNG
- B. OFCR
- C. OFNR
- D. OFNP
正解:C
質問 # 81
Which of the following fire ratings refers to the time period that a fire-rated assembly can resist flame passage?
- A. W rating
- B. T rating
- C. F rating
- D. L rating
正解:C
質問 # 82
What is the minimum recommended height that should be used when mounting a plywood back board in a telecommunication space?
- A. AFF 200 mm (8")
- B. AFF 150 mm (6")
- C. 100 mm (4")
- D. AFF 300 mm (12") AFF
正解:A
質問 # 83
Which of the following is a floor serving space that serves as a point of termination for horizontal and backbone cables?
- A. EF
- B. ER
- C. TR
- D. TE
正解:C
質問 # 84
Which of the following is designed to provide protection from harmful chemicals?
- A. Leather gloves
- B. Rubber gloves
- C. Cut-resistant gloves
正解:B
質問 # 85
What is the minimum recommended amount of vertical clearance for open-top cable supports?
- A. 150 mm (6")
- B. 100 mm (4")
- C. 75 mm (3")
- D. 125 mm (5")
正解:C
質問 # 86
How much sheath of the cable needs to be removed in order to properly terminate an 8P8C?
- A. 25mm (1")
- B. 38 mm (1.5")
- C. 12.7mm (0.5")
- D. 6.3mm (0.25")
正解:C
質問 # 87
What is the primary difference between an Equipment Rack and a Cabinet, as referenced in BICSI documentation?
- A. A rack provides open mounting rails, whereas a cabinet has doors or side panels for equipment protection
- B. A cabinet requires no grounding or bonding, whereas a rack must be grounded
- C. An equipment rack is used for fiber while a cabinet is used for copper only
- D. Cabinets can only be installed on exterior walls, while racks are installed in the room interior
正解:A
質問 # 88
The information transmitted by an ICT system can originate in two fundamental forms:
- A. Synchronous and asynchronous
- B. Progressive and regressive
- C. Analog and digital
- D. Light and sound
正解:C
質問 # 89
What is the minimum number of consolidation points that should serve an open office furniture cluster?
- A. 0
- B. 1
- C. 2
- D. 3
正解:D
質問 # 90
Which of the following is a property of an electromagnetic field built around a conductor that opposes any changes in current flow in a circuit?
- A. Impedance
- B. Capacitance
- C. Resistance
- D. Inductance
正解:D
質問 # 91
The horizontal distance from the base of the ladder to the supporting wall should be ____ percent the working length of the ladder.
- A. 0
- B. 1
- C. 2
- D. 3
正解:A
質問 # 92
Which of the following is used to express system gain and loss?
- A. Decibel (dB)
- B. Ohms
- C. Henries
- D. Farads
正解:A
質問 # 93
......