EMC DES-4122試験基本問題とアンサー

質問 23
Refer to the exhibit.

Match each callout to the Dell EMC PowerEdge server model shown.

正解:

解説:

 

質問 24
An engineer needs to install an additional PSU on an existing, single PSU Dell EMC PowerEdge R740. They complete the initial installation and cabling procedures. They connect an AC cable and the power distribution unit produces normal AC output. The engineer checks power management and sees that the new PSU is in the Failed state.
What task should be completed to troubleshoot this issue?

  • A. Confirm the System Input Power CAP is not set to Low
  • B. Verify the new PSU is the same type and wattage rating
  • C. Set the PSU AC redundancy to 1+0
  • D. Set the PSU AC redundancy to 1+1

正解: B

 

質問 25
What is used by the Lifecycle Controller to directly back up the server profile on a 14G Dell EMC PowerEdge server?

  • A. Network share
  • B. USB Flash drive
  • C. IDSDM SD card
  • D. vFlash SD card

正解: A

 

質問 26
After completing a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster the expense of slowing users down.
Which setting should be changed?

  • A. Rebuild Rate in the iDRAC GUI
  • B. System Profile to Performance in the BIOS settings
  • C. System Profile to Performance in the iDRAC GUI
  • D. Rebuild Rate in the BIOS settings

正解: A

 

質問 27
A technician is creating a virtual disk in the iDRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016 They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard Only the first 2048 GB on the virtual disk can be partitioned How should the technician obtain access to the remaining 2 TB (approximately) of storage?

  • A. Upgrade to a newer version of the operating system
  • B. Use F2 to go into the BIOS, change the BIOS boot mode to UEFI, and try again
  • C. Delete the 4 TB virtual disk and create a virtual (boot) disk no larger than 2048 GB
  • D. Use the Lifecycle Controller OS Deployment Wizard to deploy the OS on this server

正解: A

 

質問 28
Which processor configuration is used by the Dell EMC PowerEdge R740 server?

  • A. 4 socket Intel
  • B. 4 socket AMD
  • C. 2 socket AMD
  • D. 2 socket Intel

正解: D

 

質問 29
Match each status LED indicator on the Dell EMC 14G PowerEdge server with its corresponding condition.

正解:

解説:

 

質問 30
A technician working with a Dell EMC PowerEdge 1 take corrective action?

  • A. Check the LCC Log
    Check PSU LED
    Reseat the PSU
  • B. Check the LCC Log
    Check PSU LED
    Reseat the CPU
  • C. Check the System Event Log
    Check PSU LED
    Do a virtual reseat of the iDRAC
  • D. Check the System Event Log
    Check PSU LED
    Reseat the PSU

正解: C

 

質問 31
What happened on April 30, 2019?


Note: It is necessary to dose (x) the simulator window before you can select a response to this question.

  • A. Option B
  • B. Option D
  • C. Option A
  • D. Option C

正解: D

 

質問 32
What is a consideration when populating DIMMs with different types of persistent memory in a Dell EMC PowerEdge 14G server?

  • A. NVDIMMs cannot be mixed with RDlMMs
  • B. LRDIMMs can be mixed only with RDlMMs
  • C. RDlMMs can be mixed only with NVDIMMs
  • D. NVDIMMs can be mixed only with LRDIMMs

正解: D

 

質問 33
What is the correct order of steps taken during the BIOS/UEFI Recovery process?

正解:

解説:

 

質問 34
What are the default settings used when applying firmware and a configuration to a replaced part using the Lifecycle Controller?

  • A. Firmware Disabled
    Configuration Apply only if firmware match
  • B. Firmware: Match firmware of replaced part
    Configuration Apply always
  • C. Firmware: Upgrade to latest available version
    Configuration Apply always
  • D. Firmware Allow version upgrade only
    Configuration: Disabled

正解: B

 

質問 35
What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge 14G servers?

  • A. Ensures that the server has a valid Service Tag number
  • B. Ensures that the server boots only when connected to a verified network
  • C. Ensures that no unauthorized BIOS or firmware codes are run
  • D. Ensures that the installed operating system is authentic

正解: C

 

質問 36
What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?

  • A. Quad-level cell
  • B. Write Intensive
  • C. Read Intensive
  • D. Single-level cell

正解: D

 

質問 37
For security reasons, the Dell EMC PowerEdge server power button must be disabled. Use the System Setup Utility in the simulator to disable the power button. When you have finished using the simulator, click Next.

正解:

解説:
Send us your suggestion for this simulation task.

 

質問 38
What is the Open Compute Project (OCP) card used for in a Dell EMC PowerEdge server?

  • A. Fixed networking card
  • B. Provide a hot-swap component
  • C. Consume a PCIe slot
  • D. Flexibility to choose interconnects

正解: A

 

質問 39
An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment The inventory consists of:

The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb What additional component(s) is needed for this configuration?

  • A. C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord - qty 2
  • B. Dell Networking, cable, 40GbE (QSFP+) to 4 x 10GbE SFP+ passive copper breakout cable, 3 meters - qty 2
  • C. Hot-plug power supply, 1100W - qty 1
  • D. Hot-plug power supply, 750 W - qty 1

正解: A

 

質問 40
An engineer wants to fully leverage Microsoft Windows Server 2016 for TPM-based guarded host deployment of a 14G server Which BIOS settings need to be used for installing the Windows server?
A)

B)

C)

D)

  • A. Option B
  • B. Option D
  • C. Option A
  • D. Option C

正解: D

 

質問 41
Starting from which Dell EMC PowerEdge server hardware generation is the Micro SD card in the IDSDM/vFlash module supported?

  • A. 14G
  • B. 13G
  • C. 11G
  • D. 12G

正解: A

 

質問 42
Which type of access is known as Firmware RACADM on a Dell EMC PowerEdge server?

  • A. Accessing RACADM with OpenManage software
  • B. Accessing RACADM running the Dell Toolkit
  • C. Logging into iDRAC using SSH or Telnet
  • D. Logging into iDRAC through Boot Manager

正解: C

 

質問 43
A Dell EMC PowerEdge R740 server requires a vFlash SD card urgently. Additional vFlash Cards and components from other servers are available.
What is the recommended solution?

  • A. Reuse an existing vFlash SD card from either a 13G or 14G server
  • B. Reuse an existing vFlash SD card from a 14G server
  • C. Use a configuration option to convert an NVMe drive to a virtual vFlash
  • D. Use a configuration option to convert BOSS to a virtual vFlash

正解: B

 

質問 44
A system engineer has a 14G Dell EMC Poweredge server with an amber light blinking. The engineer must pull a SupportAssist collection before calling Dell Support to evaluate what the potential problem. Use the simulator to collect and view the SupportAssist collection.

正解:

解説:
Send us your suggestion for this simulation task.

 

質問 45
What are key values related to systems management when deploying OpenManage Enterprise wit Dell EMC PowerEdge servers?

  • A. Simplify
    Unify
    Automate
    Secure
  • B. Simplify
    Fee-based license Agent-free Management Secure
  • C. Simplify
    Basic Hardware Element Management
    Agent-free Management
    Fee-based license
  • D. Automate
    Basic Hardware Element Management
    Agent-free Management
    Simple and effective

正解: B

 

質問 46
Match each RAID level to its characteristic.

正解:

解説:

 

質問 47
......

2022年最新のリアルな無料EMC DES-4122試験問題集問題と解答:https://www.jpntest.com/shiken/DES-4122-mondaishu

DES-4122練習テストエンジン購入前に試そう60試験問題:https://drive.google.com/open?id=1KwVe4r6zmxNC14Bqe7j-BLkO_Xs_bzrf

弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

オンラインサポート時間:( UTC+9 ) 9:00-24:00
月曜日から土曜日まで

サポート:現在連絡