[2024年10月] 最新のDell Storage D-PVM-OE-23試験解答豪華セット問題集 [Q93-Q110]

Share

[2024年10月] 最新のDell Storage D-PVM-OE-23試験解答豪華セット問題集

EMCコンテンツをマスターしてD-PVM-OE-23試験合格保証つき問題集!

質問 # 93
When setting the TimeFinder SnapVX time-to-live with the symsnapvx command and parameter - delta 24, what does the -delta parameter specify?

  • A. Days
  • B. Minutes
  • C. Weeks
  • D. Hours

正解:A


質問 # 94
Which type of Unisphere for PowerMax deployment is represented in the graphic?

  • A. Remote
  • B. Local
  • C. Embedded
  • D. Standalone

正解:B


質問 # 95
Which component of a VMAX All Flash array is responsible for inline compression?

  • A. Management Module Control Station
  • B. Cache
  • C. Back-end module
  • D. I/O module

正解:D


質問 # 96
At which level does Non-Disruptive Migration work?

  • A. Disk Group
  • B. Storage Group
  • C. Port Group
  • D. Initiator Group

正解:B


質問 # 97
At which levels are FAST performance metrics collected in a VMAX3 array?

  • A. Disk Group, Data Pool, and thin device sub-LUN
  • B. Disk, Data Pool, and Storage Resource Pool
  • C. Data Pool, Storage Resource Pool, and Storage Group
  • D. Disk Group, Storage Group, and thin device sub-LUN

正解:D


質問 # 98
A company has two VMAX3 arrays installed at two different sites. VMAX3 eNAS is configured on both arrays with IP network connectivity between them. The company wants to replicate file data between the two VMAX3 arrays.
Which EMC technology will meet the requirement without additional hardware?

  • A. Replicator
  • B. RecoverPoint
  • C. TimeFinder
  • D. SRDF

正解:A


質問 # 99
What is the correct sequence of steps to obtain PowerMax licenses and ensure the PowerMax is configured to allow the licensed features to work properly?

正解:

解説:


質問 # 100
Which Unisphere for VMAX drop-down menu allows users to set up a migration environment?

  • A. Hosts
  • B. Data Protection
  • C. Storage
  • D. System

正解:B


質問 # 101
Where is the automatic backup feature for the Solutions Enabler Group Name Services (GNS) database set?

  • A. SYMAPI options file
  • B. Installation wizard
  • C. Daemon options file
  • D. Unisphere for VMAX

正解:C


質問 # 102
Which VMAX3 FAST algorithm is the basis for the Optimized Service Level Objective?

  • A. Disk resource protection
  • B. SLO capacity compliance
  • C. SRP capacity compliance
  • D. SLO response time compliance

正解:A


質問 # 103
A Unisphere for VMAX administrator is creating a new user. The new user needs the ability to provision storage from the VMAX3 array. However, the administrator does not want the user to create or delete other users.
Which role should be assigned to this user?

  • A. Administrator
  • B. PerfMonitor
  • C. SecurityAdmin
  • D. StorageAdmin

正解:D


質問 # 104
A Unisphere for PowerMax administrator is creating a new user. The new user needs the ability to provision storage from the PowerMax array. However, the administrator does not want the user to create or delete other users.
Which role should be assigned to this user?

  • A. Administrator
  • B. PerfMonitor
  • C. SecurityAdmin
  • D. StorageAdmin

正解:D


質問 # 105
You are in a meeting with a customer to discuss virtual provisioning on VMAX3 arrays. The customer wants information on extent allocation during thin device creation.
How many extent(s) are allocated when a thin device is created?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:C


質問 # 106
Which Solutions Enabler daemon is responsible for monitoring conditions on PowerMax arrays and forwarding them to client applications?

  • A. storgnsd
  • B. storsrvd
  • C. storapid
  • D. storevntd

正解:D


質問 # 107
A storage administrator has set the I/O limit on a VMAX3 Storage Group to 1000 IO/sec. The I/O distribution has been set to the default mode. The Port Group has two ports from different directors; however, one of the directors has failed.
What will the I/O limit be on the director that is still online?

  • A. 750 IO/sec
  • B. 2000 IO/sec
  • C. 1000 IO/sec
  • D. 500 IO/sec

正解:D


質問 # 108
Refer to the Exhibit.

How many tracks will be returned to the pool if snapshot 'backup' generation 2 is terminated?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:C


質問 # 109
What is the recommended sequence of recovery steps for SRDF/A after an extended loss of links?

  • A. 1. Set SRDF to Asynchronous mode
    2. Set SRDF to Adaptive Copy Disk mode
    3. Enable Consistency
    4. Disable Consistency
    5. Resume the links
  • B. 1. Enable Consistency
    2. Disable Consistency
    3. Set SRDF to Adaptive Copy Disk mode
    4. Resume the links
    5. Set SRDF to Asynchronous mode
  • C. 1. Resume the links
    2. Set SRDF to Adaptive Copy Disk mode
    3. Enable Consistency
    4. Disable Consistency
    5. Set SRDF to Asynchronous mode
  • D. 1. Resume the links
    2. Set SRDF to Asynchronous mode
    3. Set SRDF to Adaptive Copy Disk mode
    4. Disable Consistency
    5. Enable Consistency

正解:C


質問 # 110
......

あなたを合格させるEMC D-PVM-OE-23試験専門問題集はここにある:https://www.jpntest.com/shiken/D-PVM-OE-23-mondaishu

最新Dell Storage D-PVM-OE-23練習テストに最速準備問題をゲットせよ:https://drive.google.com/open?id=1MIP51uk-Rwvoe2phOcvj9oZG86iGJDtv

弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

オンラインサポート時間:( UTC+9 ) 9:00-24:00
月曜日から土曜日まで

サポート:現在連絡