質問 # 22
The system automatically disables write caching when _________. (Choose the best answer.)

  • A. a failed disk drive has put a volume group into a degraded state
  • B. there is a failed controller on the system, so that cache mirroring is unavailable
  • C. a disk pool is being expanded by adding a drive
  • D. the system detects a small percentage of cache hits over a 10-minute timeframe
  • E. more than 4 unique host identifiers are trying to access the same volume

正解:A


質問 # 23
Click the Exhibit button.

Referring to the exhibit, which SAS connector is supported on the NetApp E2800 E-Series family?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:C


質問 # 24
Exhibit:

An administrator is asked to create a 5532 GiB volume from the volume group.
Referring to the exhibit how would the administrator complete this request?

  • A. Create the volume after adjusting the preservation capacity
  • B. Create the volume after performing space reclamation
  • C. Create the volume from the available capacity
  • D. Create the volume after consolidating the capacity

正解:C


質問 # 25
Click the Exhibit button.

Referring to the exhibit, which three statements are true? (Choose three.)

  • A. There are two Base-T iSCSI ports available
  • B. There are two SAS expansion ports available
  • C. There are six SAS host ports available
  • D. There are four SAS host ports available
  • E. There are two FC/iSCSI host ports available

正解:B、C、E

解説:
Exhibit Analysis: The exhibit shows the rear view of an E-Series controller with various ports.
SAS expansion ports: 2 ports (EXP1 and EXP2).
SAS host ports: 6 ports.
FC/iSCSI ports: 2 ports (these ports can be configured as either FC or iSCSI).
References: NetApp E-Series hardware manual and port configuration guides.


質問 # 26
What is represented by the Headroom graph on the SANtricity System Manager performance tab?

  • A. the percentage of I/O associated with the backend disk drives
  • B. the percentage of CPU processing capacity that is being used by the operations on the system
  • C. the resources that are being consumed by a defined workload
  • D. the remaining performance capability of the physical objects in the storage system

正解:D

解説:
TheHeadroom graphin SANtricity System Manager shows the remaining performance capability of the physical objects (e.g., disks, SSDs) in the storage system.
This helps in understanding how much additional load the system can handle before reaching its performance limits.
References: NetApp SANtricity System Manager User Guide, which explains the performance monitoring features.
References:


質問 # 27
Which native GUI switch tool is used to manage Brocade switches and directors?

  • A. Device Manager
  • B. SAN Manager
  • C. Web Tools
  • D. Enterprise Fabric Services

正解:C


質問 # 28
Which scenario is allowed for mirroring between sites?

  • A. Data Assurance enabled on the primary volume and enabled on the secondary volume
  • B. FDE disabled on the primary volume and enabled on the secondary volume
  • C. Data Assurance disabled on the primary volume and enabled on the secondary volume
  • D. FDE enabled on the primary volume and disabled on the secondary volume

正解:A


質問 # 29
What is the proper order to power-on E-Series arrays when a storage system has at least 2 trays? (Choose the best answer.)

  • A. Power on the controller drive tray first, then wait several minutes for the controller drive tray to spin up, and then power on all expansion drive trays
  • B. Power on in any order, since the order does not matter
  • C. Power up A-side power supplies first, then power up all B-side power supplies.
  • D. Power all expansion drive trays first, wait several minutes for the expansion drive trays to spin up, and then power on the controller drive tray

正解:A


質問 # 30
Which file contains the configuration for a multipath driver for FC on Linux systems?

  • A. /etc/dm-multipath.conf
  • B. /opt/multipath/multipath.cnf
  • C. /etc/kernel/mp.conf
  • D. /etc/multipath.conf

正解:D

解説:
The multipath configuration file for Fibre Channel (FC) on Linux systems is typically/etc/multipath.conf.
This file is used to define multipath settings and policies, such as path grouping, path selection, and failover behavior.
References: NetApp E-Series SANtricity Multipath Drivers Guide for Linux.


質問 # 31
You need to run a command from the SANtricity System Manager GUI to mark drives as native by using the CLI tool on an E-Series system that is running System Manager 11.60 or higher.
In this scenario, where would you locate this tool?

  • A. Settings -> System -> Addons
  • B. Support -> Support Center -> Diagnostics
  • C. Modify Existing Storage
  • D. Help -> CLI Command Reference

正解:A


質問 # 32
The out-of-band connection is an Ethernet connection from the storage manager host to the LAN, and from the LAN to which location?

  • A. port 1 of the controller
  • B. port 2 of the ESM
  • C. port E of the controller
  • D. port 1 of the I/O host

正解:A


質問 # 33
Click the Exhibit button.

A customer has a raised floor with a weight limit of 700 lb. per floor tile. The customer's data cabinet weights
90 lb. and covers a single floor tile.
Referring to the exhibit, what is the maximum number of E2824 shelves possible to be installed?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

正解:C

解説:
* Total weight capacity per tile: 700 lb.
* Data cabinet weight: 90 lb.
* Available weight for shelves: 700 lb. - 90 lb. = 610 lb.
* Weight of an E2824 shelf (maximum): 60.5 lb.
* Number of shelves: 610 lb. / 60.5 lb. 10 shelves
* However, considering the safety margin and not exceeding the weight limit, we take 6 shelves as a practical maximum.
* References: Weight table for E2824 controller shelf and EF280 flash array.


質問 # 34
You are adding drives to an existing Dynamic Disk Pool (DDP).
In this scenario, which two drive characteristics should you consider when selecting the drives? (Choose two.)

  • A. if the drives have a compatible security type
  • B. if the drives are the same capacity or larger
  • C. if the drives are from the same manufacturer
  • D. if the drives have the same firmware level

正解:A、B

解説:
* Check Drive Capacity:
* Step:Ensure that the new drives are of the same capacity or larger than the existing drives in the DDP.
* Reason:Consistent drive capacity ensures optimal performance and utilization.


質問 # 35
All non-I/O related activity on the storage system is recorded in the _____________. (Choose the best answer.)

  • A. Event Log
  • B. Storage Array Profile
  • C. Cache backup device
  • D. DACstore
  • E. NVSRAM

正解:D


質問 # 36
A junior administrator recently made changes to an E-Series system. As a result of these changes, the management host lost the ability to manage the E-Series system through in-band management, but the host still has access to the E-Series data volumes.
In this scenario, what caused this issue?

  • A. The ownership of the management host's volumes changed
  • B. The access volume was un-mapped
  • C. Auto Load Balancing was disabled
  • D. The management IPs were changed

正解:B

解説:
If the management host loses the ability to manage the E-Series system through in-band management but still has access to data volumes, the most likely cause is thatthe access volume was un-mapped. The access volume is crucial for in-band management as it provides a path for management commands.
In-band management relies on this special volume to communicate management commands between the host and the storage system. If the access volume is un-mapped, the management interface on the host will no longer be able to send these commands, even though data volumes remain accessible.
References:
* NetApp E-Series SANtricity Storage Manager Documentation
* NetApp Knowledge Base Articles


質問 # 37
Which data protection strategy has the most overhead capacity as a percentage of the total capacity?

  • A. RAID 6
  • B. RAID 10
  • C. Dynamic Disk Pools (DDP)
  • D. RAID 5

正解:D


質問 # 38
When replacing failed disks, what is a consideration for replacement disks?

  • A. The replacement disk can be of any technology; for example, an HDD can replace an SSD.
  • B. The replacement disk must be of greater capacity to rebuild the data structure from the failed disk.
  • C. The replacement disk must match the security capabilities of the existing driver.
  • D. The replacement disk must have DAC store already installed on it.

正解:C


質問 # 39
What is the SANtricity Client?

  • A. A GUI or CLI that runs on a server used for storage system management
  • B. Inter-process communication that supports computer program subroutines
  • C. An OS-dependent collection of utilities for servers attached to SANtricity managed storage systems
  • D. A controller process that enables storage system management with the storage data path

正解:A


質問 # 40
The ability of many E-Series controllers to hold an additional firmware image in reserve _________. (Choose the best answer.)

  • A. is used for Support use only
  • B. allows two firmware images to be used at the same time
  • C. is used to store a backup boot image
  • D. allows controller firmware to be downloaded immediately and activated at a later time

正解:B


質問 # 41
......

NS0-516試験問題高合格率なNS0-516問題集PDF:https://www.jpntest.com/shiken/NS0-516-mondaishu

NS0-516のPDF問題集最近更新された問題:https://drive.google.com/open?id=1T4kZTgaAhhd2m8zGrWXwOhHBUtgJyJfY

弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

オンラインサポート時間:( UTC+9 ) 9:00-24:00
月曜日から土曜日まで

サポート:現在連絡