[2022年10月16日] 5V0-22.21のPDFで最近更新された問題です集試験点数を伸ばそう [Q35-Q51]

Share

[2022年10月16日] 5V0-22.21のPDFで最近更新された問題です集試験点数を伸ばそう

5V0-22.21完全版問題集には無料PDF問題で合格させる


VMware 5V0-22.21 認定試験の出題範囲:

トピック出題範囲
トピック 1
  • Identify the characteristics of the different types of encryption
  • Identify which VMware solutions integrate with vSAN
トピック 2
  • Identify how to use Skyline health check to maintain a healthy status of a vSAN cluster
  • Given a scenario, identify when and how to use vSphere Replication in combination with vSAN
トピック 3
  • Identify how to configure vSAN stretched cluster and 2-node configurations
  • Identify how to configure Cloud Native storage (CNS) with appropriate policies
トピック 4
  • Given a scenario, identify how to configure vSAN storage policies
  • Identify how to monitor vSAN with vRealize Operations
トピック 5
  • Given a scenario, identify how to upgrade an HCI environment using vSphere Lifecycle Manager (vLCM)
  • Identify the impact of vSAN storage policy changes
トピック 6
  • Given a scenario, identify how to create and remove vSAN Direct Configuration
  • Identify the architectural requirements of a standard vSAN cluster, vSAN 2-node cluster, and a vSANstretched cluster
トピック 7
  • Identify how to determine vSAN health using the UI or ESXCLI
  • Given a scenario, identify how to add and remove hosts from a vSAN cluster

 

質問 35
A vSAN administrator notices the VMware Skyline Health: Network Latency Check reports indicate three hosts are non-compliant.
Which action should the vSAN administrator take?

  • A. Place the noncompliant hosts into an isolated network.
  • B. Check VMKNICs, uplinks. VLANs. physical switches, and associated settings.
  • C. Rerun the VMware Skyline Health: vSAN Cluster Partition report.
  • D. Reboot the noncompliant hosts one at a time.

正解: C

 

質問 36
An administrator has discovered that space utilized by VMs does not decrease after deleting files and folders within the VMs. The administrator needs to be able to reclaim this space.
Which action could the administrator take to accomplish this task?

  • A. Reboot the VM to recreate the swap file.
  • B. Enable TRIM/UN MAP for the vSAN cluster.
  • C. Set the Object Space Reservation rule to 100%.
  • D. Disable Storage I/O Control for the vSAN cluster.

正解: B

 

質問 37
An administrator is responsible for managing a 5-node vSAN 7.0 cluster that hosts 150 virtual machines. Each virtual machine belongs to one of the following vSAN Storage Policies:
vSANPolicy1:
Site Disaster Tolerance: None
Failures to Tolerate: 1 failure - RAIN5 (Erase Coding)
vSANPolicy2:
Site Disaster Tolerance: None
Failures to Tolerate: No data redundancy
Following an unplanned power event within the datacenter, the administrator has been alerted to the fact that one host has permanently failed. Prior to the vSAN host failure, the usable storage capacity of the vSAN Cluster was more than 40%.
What will be the potential impact to any virtual machine that was running on the failed host using vSANPolicy2?

  • A. Each virtual machine will be restarted on another vSAN host using vSphere HA.
  • B. After 60 minutes, vSAN will automatically start the recovery process.
  • C. Each virtual machine will need to be restored from backup.
  • D. vSAN will immediately start the recovery process.

正解: C

 

質問 38
The objects on a 4-node vSAN cluster are assigned a RAID-5 policy. A network outage occurs, causing host one to lose connectivity with the rest of the cluster. Seventy-five minutes have elapsed.
What is the health state of the objects?

  • A. Reduced availability
  • B. Non-availability related incompliance (non-compliance)
  • C. Reduced availability with no rebuild - delay timer
  • D. Reduced availability with no rebuild

正解: D

解説:
Minimum number of hosts required for Raid 5: 2n+1.
Reduced availability - active rebuild: The object has suffered a failure, but it was configured to be able to tolerate the failure. I/O continues to flow and the object is accessible. vSAN is actively working on re-protecting the object by rebuilding new components to bring the object back to compliance.
Reduced availability with no rebuild: The object has suffered a failure, but VSAN was able to tolerate it. For example: I/O is flowing and the object is accessible. However, VSAN is not working on re-protecting the object. This is not due to the delay timer (reduced availability - no rebuild - delay timer) but due to other reasons. This could be because there are not enough resources in the cluster, or this could be because there were not enough resources in the past, or there was a failure to re-protect in the past and VSAN has yet to retry.

 

質問 39
An administrator is enabling vSphere HA and vSAN on the same cluster and needs to use a configuration that is valid for vSphere HA Heartbeat datastore.
Which configuration should be used?

  • A. vSAN datastore as vSphere HA Heartbeat datastore
  • B. Any datastore mounted to more than one host, but not a vSAN datastore
  • C. A datastore mounted to more than one host, as well as any vSAN datastore
  • D. Any datastore mounted to more than one host

正解: B

 

質問 40
A vSAN administrator has three available racks and six vSAN hosts and needs to protect against a rack failure while maximizing resources.
Which two strategies should the vSAN administrator use to achieve this goal? (Choose two.)

  • A. Specify fault domains
  • B. RAID-6/FTT=2
  • C. vSAN stretched cluster
  • D. 2-node configuration
  • E. RAID-5/FTT=1

正解: A,B

 

質問 41
An organization is facing vSAN storage capacity challenges on one of their vSAN enabled clusters, while other vSAN enabled clusters are underutilized. The current vSAN version is 7.0 U1.
Which vSAN feature should be used to resolve this challenge in the quickest way?

  • A. vSANHCIMesh
  • B. vSAN Replication
  • C. vSAN Stretched Clusters
  • D. vSAN Datastore(s)

正解: A

 

質問 42
A site administrator has determined that the site needs to upgrade all vSAN clusters to 7.0 U1. The vSAN administrator wishes to complete the update in the shortest amount of time possible. All virtual machines are assigned a storage policy where the "Failures to tolerate" is set to one or higher.
Which strategy should be used to achieve this goal?

  • A. Update only select, mission-critical clusters.
  • B. Select the *No data migration" maintenance mode option.
  • C. Perform a complete update, omitting the on-disk format update.
  • D. Disable de-duplication and compression prior to the upgrade.

正解: A

 

質問 43
Which two requirements should the vSAN administrator consider in order to accomplish this goal? (Choose two.)

  • A. Either Layer 2 and Layer 3 communications can be used.
  • B. NIC teaming must be implemented for the vSAN network vmkernel port.
  • C. Encryption must be disabled prior to configuring HCI mesh.
  • D. A leaf spine topology is required for core redundancy and reduced latency.
  • E. The configuration must meet the same latency and bandwidth requirement as local vSAN.

正解: A,B

 

質問 44
Which two conditions should be verified before removing an ESXi host from a vSAN cluster? (Choose two.)

  • A. Encryption is disabled
  • B. Resyncs are running
  • C. Data evacuation is complete
  • D. ESXi host is in maintenance mode
  • E. Performance Service is disabled

正解: C,D

 

質問 45
An administrator has deployed a development VMware vSAN 7.0 U1 cluster. It will be used by the development teams to deploy a mixture of cloud-native stateful applications alongside a combination virtual machine and Kubernetes workloads.
Which vSAN feature should be configured for the vSAN Data Persistence platform (vDPp)?

  • A. vSAN Direct
  • B. vSAN with Shared Nothing Architecture (SNA)
  • C. vSAN Cloud Native Storage
  • D. vSAN File Services

正解: A

 

質問 46
After a server power failure, the administrator noticed the scheduled resyncing in the cluster monitor displays objects to be resynchronized under the pending category.
What are these objects in this category?

  • A. Object resynchronization must be started manually.
  • B. The delay timer has not expired.
  • C. There are too may objects to be synchronized.
  • D. These objects belong to virtual machines, which are powered off.

正解: A

 

質問 47
A new host with local storage devices has been added to a vSAN cluster. Now, the administrator would like to increase the capacity of the vSAN datastore.
What must be done to the new host to accomplish this goal?

  • A. Perform a storage device rescan.
  • B. Delete all existing partitions.
  • C. Create one or more disk groups.
  • D. Configure a RAID set on the storage controller.

正解: B

 

質問 48
A vSAN administrator is troubleshooting poor performance of vSAN cluster while vCenter is not available. The vSAN administrator decides to use a command line tool to monitor real-time vSAN IOPS, throughput, and other metrics on ESXi host.
Which command line tool should be used?

  • A. esxcli
  • B. vimtop
  • C. vsantop
  • D. esxcfg

正解: C

 

質問 49
After a recent security assessment, the security team recommended that vSAN encryption be enabled. The vSAN administrator will be adding a Key Management Server to vCenter.
What is a prerequisite to taking this action?

  • A. Proxy server with username and password access
  • B. IPv6 addressing
  • C. Self-encryption drives
  • D. Cryptographer ManageKeyServer permissions

正解: D

 

質問 50
A 100GB virtual disk object has this storage policy assigned to it:
Site disaster tolerance: None - standard cluster
Failures to Tolerate: 1 failure - RAID-1 (Mirroring)
Number of disk stripes per object: 3
What is the maximum amount of raw vSAN storage capacity consumed by this virtual disk?

  • A. 100GB
  • B. 600GB
  • C. 300GB
  • D. 200GB

正解: A

 