2025年最新の実際に出る無料Huawei H19-308_V4.0試験問題集と解答 [Q51-Q71]

Share

2025年最新の実際に出る無料Huawei H19-308_V4.0試験問題集と解答

H19-308_V4.0練習テストエンジンで今すぐ試そう200試験問題

質問 # 51
Smart Virtualizaion enables unified management for heterogeneous storage resources.

  • A. FALSE
  • B. TRUE

正解:B


質問 # 52
What enable Dorado V6 to deliver such high performance?

  • A. Smart disk enclosure collaboration algorithm
  • B. End-to-end NVMe protocol
  • C. Higher performance provided by HDDs
  • D. Five Huawei-developed chips

正解:A、B、C


質問 # 53
SmartQoS allows preferential response to high-priority services.

  • A. FALSE
  • B. TRUE

正解:B


質問 # 54
Which sizes of cache can be used in the OceanStor 5500 V5? (Multiple Choice)

  • A. 128 GB (dual controllers)
  • B. 64 GB (dual controllers)
  • C. 256 GB (dual controllers)

正解:A、C


質問 # 55
Which is the correct formation order of the following elements in RAID 2.0+?

  • A. LD -> CKG -> CK -> Extent -> LUN
  • B. LD -> Extent -> CKG -> CK -> LUN
  • C. LUN -> CK -> CKG -> Extent -> LD
  • D. LD -> CK -> CKG -> Extent -> LUN

正解:C


質問 # 56
Which advantages does Dorado V3 have in the database acceleration scenario? (Multiple Choice)

  • A. No impact on performance after enabling of snapshot
  • B. High lOPS
  • C. Low latency
  • D. No impact on performance after enabling of inline compression
  • E. Gateway-free active -a ctive, for optimal reliability

正解:A、B、C、D、E


質問 # 57
Which are the advantages of Dorado V3? (Multiple Choice)

  • A. 3x data reduction guarantee, 50% TCO saving
  • B. 4 million IOPS at 0.5 ms latency 10X storage performance improvement 1 ms gateway-free active-
  • C. Simplified management, deployment in 10 minutes
  • D. active solution 99.9999% field-proven availability

正解:A、B、D


質問 # 58
Which technologies are typically used for data reduction?

  • A. Inline deduplication
  • B. Post deduplication
  • C. Compression
  • D. RAID

正解:A、B、C


質問 # 59
What are the highlights of the OceanStor V5 in convergence?

  • A. A combination of SAN and NAS advantages, ensuring industry-leading functions and performance
  • B. Non disruptive data migration from third party devices
  • C. Data flows between the OceanStor Dorado, F V5, V5, andV3
  • D. HyperMetro for both SAN and NAS scalable to the 3DC version

正解:A、B、C、D


質問 # 60
Which of these is the same between OceanStor V5 and OceanStor V3?

  • A. The software is the same.
  • B. The hardware platform is the same.

正解:A


質問 # 61
SmartMigration supports three data migration approaches: Storage media migration (for example, between SAS and NL-SAS), RAID level migration (between different RAID levels), and conversion between a thin LUN and a thick LUN.

  • A. FALSE
  • B. TRUE

正解:B


質問 # 62
How does Dorado V3 help customers save costs? (Multiple Choice)

  • A. Less space occupation
  • B. Lower power consumption
  • C. Lower maintenance costs
  • D. High performance, same performance with fewer devices
  • E. Data reduction, lower storage capacity to be bought

正解:A、B、C、D、E


質問 # 63
What are the characteristics of the HyperMetro for Both SAN and NAS supported by the OceanStor V5 series? (Multiple Choice)

  • A. Load balancing between active-active sites
  • B. Active-active solution with RPO=0 and RTO RT0
  • C. Gateway-free, SAN and NAS integration

正解:A、B、C


質問 # 64
The OceanStor 2200 V3 does not support scale-out.

  • A. FALSE
  • B. TRUE

正解:B


質問 # 65
Which storage technologies provide redundancy protection?

  • A. RAID 10
  • B. RAID 5
  • C. RAID 0
  • D. RAID 1

正解:A、B、D


質問 # 66
Each LUN on Dorado V6 is owned by a specific controller.

  • A. True
  • B. False

正解:A


質問 # 67
FlashLink involves which of the following technologies:

  • A. Scale-up and Scale-out
  • B. Sequential write of large blocks
  • C. Independent metadata data partitioning
  • D. I/O priority adjustment

正解:A、B、C、D


質問 # 68
OceanStor 9000 supports ______ editing of media?

  • A. 2-layer4K
  • B. 20-layer4K
  • C. 6-layer 4K
  • D. 10-layer4K

正解:C


質問 # 69
OceanStor F V5 series are hybrid-flash storage systems.

  • A. FALSE
  • B. TRUE

正解:A


質問 # 70
Which protocol is not a front-end protocol of SAN?

  • A. iSCSI
  • B. InfiniBand
  • C. NFS
  • D. Fiber Channel
  • E. FCoE

正解:C


質問 # 71
......

試験合格保証付きのHCS-Pre-sales H19-308_V4.0試験問題集:https://www.jpntest.com/shiken/H19-308_V4.0-mondaishu

Huawei H19-308_V4.0日常練習試験は2025年最新のに更新された200問あります:https://drive.google.com/open?id=1tgdhKrt7KDONGb8hbz2nOujPBgSSsLyq

弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

オンラインサポート時間:( UTC+9 ) 9:00-24:00
月曜日から土曜日まで

サポート:現在連絡