VMware 5V0-31.22リアル試験問題解答は無料 [Q27-Q52]

Share

VMware 5V0-31.22リアル試験問題解答は無料

試験問題集で5V0-31.22練習無料最新のVMware練習テスト


VMware Cloud Foundation Specialist(v2)認定を取得することで、ITプロフェッショナルは自身のVMware技術に関する専門知識を証明し、キャリアを進めることができます。また、クラウドベースのソリューションを採用する組織が増える中、求職市場においても競争優位性を得ることができます。VMware 5V0-31.22試験に合格することで、候補者はVMware Cloud Foundation環境の設計、実装、管理に関するスキルを示すことができ、どの組織においても貴重なアセットとなるでしょう。

 

質問 # 27
An architect needs to enable the workload management for a VCF VI workload domain and plans on using the minimum requirement for deploying a highly available NSX edge cluster.
What is the minimum requirement for this deployment?

  • A. A cluster of two large NSX edge nodes
  • B. A cluster of three large NSX edge node
  • C. A cluster of one large NSX edge node
  • D. A cluster of two small NSX edge nodes

正解:A

解説:
Explanation
This is because according to VMware documentation1, a VI workload domain consists of one or more vSphere clusters that run customer workloads. To enable workload management for a VI workload domain, you need to have an NSX-T edge cluster that provides north-south connectivity and load balancing for Kubernetes clusters
2. The minimum requirement for creating an NSX-T edge cluster is two edge nodes34. The size of the edge nodes depends on the throughput and features required, but for high availability, large size is recommended5.
https://docs.vmware.com/en/VMware-Cloud-Foundation/4.5/vcf-getting-started/GUID-C68FD810-D270-43F2-A


質問 # 28
Which two functionalities does a NSX Tier-0 Gateway provide to a vSphere with Tanzu deployment? (Choose two.)

  • A. Connectivity to physical networks and routers
  • B. Downlink Connections to Segments
  • C. Gateway for Segments
  • D. Layer 2 Switching
  • E. Connectivity to all Tier-1 Gateways

正解:A、E

解説:
Explanation
According to About Architecture and Design for a vSphere with Tanzu Workload Domain4, two of the functionalities that a NSX Tier-0 Gateway provides to a vSphere with Tanzu deployment are:
* Connectivity to all Tier-1 Gateways: A Tier-0 Gateway connects to one or more Tier-1 Gateways that provide routing services for each namespace in vSphere with Tanzu.
* Connectivity to physical networks and routers: A Tier-0 Gateway connects to external networks via uplink interfaces that can use static routing or dynamic routing protocols such as BGP.


質問 # 29
An architect is designing networking for a developer-ready infrastructure on VMware Cloud Foundation.
During the discussion with the network team, a question comes up about the use of a routable CIDR range.
Which item uses this type of range?

  • A. Ingress
  • B. Kubernetes services
  • C. vSphere Pod
  • D. ClusterIP

正解:A

解説:
Explanation
This is because an ingress is a Kubernetes resource that exposes HTTP and HTTPS routes from outside the cluster to services within the cluster1. An ingress can use a routable CIDR range to assign IP addresses to the ingress controllers that handle the traffic routing.


質問 # 30
A VMware Cloud Foundation administrator has been tasked with replacing self-signed certificates with those signed by a third-party Certificate Authority. A security policy disallows the integration and use of Microsoft Active Directory Certificate Sen/ices and prefers an external provider.
Which two steps must be taken in order to configure these certificates? (Choose two.)

  • A. Create and package the certificates in a domain_name.tar.gz file
  • B. Ensure that the external provider has Administrator rights in vCenter.
  • C. Generate Certificate Signing Requests from SDDC Manager.
  • D. Generate public-private key pairs using the external provider.
  • E. Use the sddcmanager-ssl-util.sh utility to list and delete existing certificates.

正解:A、C

解説:
Explanation
Generate Certificate Signing Requests from SDDC Manager - In order to replace the self-signed certificates with third-party signed certificates, the Certificate Signing Requests (CSRs) need to be generated. This can be done from the SDDC Manager UI.
Create and package the certificates in a domain_name.tar.gz file - After the CSRs are generated, they can be used to obtain third-party signed certificates from a certificate authority. Once the certificates are obtained, they need to be packaged in a domain_name.tar.gz file and uploaded to SDDC Manager.
* Generate Certificate Signing Requests (CSRs) from SDDC Manager for each component that requires a certificate1. You can do this from the SDDC Manager UI or using an API call1.
* Have the CSRs signed by a third-party Certificate Authority of your choice1. You can use any external provider that meets your security policy requirements.
* Create and package the certificates in a domain_name.tar.gz file according to the naming convention and folder structure specified by SDDC Manager . You can use any compression tool that supports gzip format.
* Upload and install the certificates using SDDC Manager UI or API . You can also verify and troubleshoot the certificate installation using SDDC Manager.
https://docs.vmware.com/en/VMware-Cloud-Foundation/4.5/vcf-admin/GUID-80431626-B9CD-4F21-B681-A8


質問 # 31
A systems administrator has recently added newly-commissioned hosts in the the VI workload domain, and IP addresses are automatically configured to their associated network pool. The administrator reviews which storage options require only vMotion and NFS networks in the network pool.
Which two storage options have this requirement? (Choose two.)

  • A. vSAN and NFS
  • B. vSAN
  • C. Wols on ISCSI
  • D. NFS
  • E. vVols on NFS

正解:B、D

解説:
Explanation
According to the VMware Cloud Foundation documentation on network requirements, vSAN requires only the vMotion and NFS networks to be configured in the network pool. This is because vSAN traffic can be carried over the vMotion network, and the NFS network is needed to support the use of NFS datastores [1].
NFS is a file-based storage protocol that can be accessed over IP networks. It does not require any special hardware or software, and can be accessed by any device that supports the NFS protocol [2]. As such, it only requires the NFS network to be configured in the network pool.
Therefore, the correct answers are B. NFS and E. vSAN.


質問 # 32
Which three options are valid use cases for multiple clusters in a workload domain? (Choose three.)

  • A. One cluster distributed across two racks and one workload domain
  • B. Two clusters forming one stretched workload domain
  • C. One cluster stretching two workload domains
  • D. Workload domain with multiple clusters in one rack
  • E. Workload domain with multiple availability zones each containing clusters
  • F. One stretched cluster across two regions and two workload domains

正解:B、D、E

解説:
Explanation
These are valid use cases for multiple clusters in a workload domain according to VMware documentation. A workload domain with multiple availability zones each containing clusters can provide high availability and disaster recovery by distributing workloads across different physical locations within a region. A workload domain with multiple clusters in one rack can provide scalability and flexibility by allowing different configurations and policies for different clusters within a single logical unit. Two clusters forming one stretched workload domain can provide resiliency and fault tolerance by synchronizing data across two sites within a region.


質問 # 33
Which three components are required to deploy a stretched cluster in a VMware Cloud Foundation environment? (Choose three.)

  • A. vSAN: host overlay and vMotion network per data site
  • B. vSAN, host overlay and vMotion network stretched across both sites
  • C. DHCP on the host overlay network
  • D. DHCP on the NSX Edge overlay network
  • E. One witness host per vSAN stretched cluster
  • F. One witness host per site

正解:B、C、E

解説:
Explanation
This is because when deploying a stretched cluster in a VMware Cloud Foundation environment, you must ensure that:
* The vSAN network, the host overlay network and the vMotion network are stretched across both availability zones12. These networks enable data replication, communication and migration between hosts in different sites.
* The host overlay network has DHCP enabled to provide IP addresses to hosts1. This simplifies the configuration and management of hosts in different sites.
* Each vSAN stretched cluster has one witness host deployed in a separate location from both availability zones12. The witness host acts as a tie-breaker in case of a site failure or split-brain scenario.
https://docs.vmware.com/en/VMware-Cloud-Foundation/4.5/vcf-admin/GUID-7B4CC729-20BD-4CC9-B855-B


質問 # 34
A VMware administrator is tasked to upgrade a VMware Cloud Foundation (VCF) environment that is running on DellEMC PowerEdge servers.
During the ESXi software upgrade for the VI Workload Domain hosts, the administrator receives an error stating that the correct storage driver is not available, although the storage adapters are enabled in the BIOS.
Which action should the administrator take to fix this issue?

  • A. Use the image for the ESXi build in the VCF bill of materials.
  • B. Upgrade the BIOS firmware to the latest version.
  • C. Use the Dell EMC customized image for the ESXi build in the VCF bill of materials.
  • D. Upgrade the storage adapter firmware to the latest version.

正解:C

解説:
Explanation
when upgrading ESXi software on Dell EMC PowerEdge servers using SDDC Manager Lifecycle Management (LCM), you must use a Dell EMC customized image that contains drivers for specific hardware components such as storage adapters.
https://docs.vmware.com/en/VMware-vSphere/6.7/com.vmware.vsphere.virtualsan.doc/GUID-08911FD3-2462-


質問 # 35
VCF design workshops were conducted, and the architect collected the following customer requirements for the newly planned VCF infrastructure:
* The new VCF infrastructure must target two zones: DEV/UAT and DMZ.
* The security team would like to have full management and network isolation between these two zones
* 12 hosts have been ordered for the solution.
* DEV/UAT workloads must comply with an erasure coding vSAN storage policy with the ability to tolerate the failure of two hosts.
Which workload domain sizing will be required to achieve these requirements?

  • A. 8-hosts DEV/UAT workload domain, having an 8-hosts DEV/UAT cluster, and a 4-hosts DMZ workload domain, having a 4-hosts DMZ cluster
  • B. 12-hosts workload domain for both zones, having a 4-hosts DEV cluster a 4-hosts UAT cluster, and a
    4-hosts DMZ cluster
  • C. 12-hosts workload domain for both zones, having an 8-hosts DEV/UAT cluster, and a 4-hosts DMZ cluster
  • D. 8-hosts DEV/UAT workload domain, having a 4-hosts DEV cluster and a 4-hosts UAT cluster, in addition to a 4-hosts DMZ workload domain, having a 4-hosts DMZ cluster

正解:A

解説:
Explanation
erasure coding vSAN storage policy with the ability to tolerate two host failures requires at least six fault domains (hosts) in a cluster. Therefore, an 8-hosts cluster can meet this requirement for DEV/UAT workloads.
Additionally, creating separate workload domains for DEV/UAT and DMZ can provide full management and network isolation between these two zones.
https://docs.vmware.com/en/VMware-vSphere/6.7/com.vmware.vsphere.virtualsan.doc/GUID-AD408FA8-5898


質問 # 36
A VCF administrator is preparing to configure scheduled backups for the SDDC Manager. What must the administrator register as an external component to complete this task?

  • A. SMB server
  • B. SFTP server
  • C. iSCSI server
  • D. NFS server

正解:B

解説:
Explanation
This is because according to VMware documentation, this is what an administrator must register as an external component to complete this task of configuring scheduled backups for the SDDC Manager. SFTP server is one of the supported backup targets for SDDC Manager backups. The administrator can register an SFTP server by navigating to the SDDC Manager UI > Administration > Backup > Site Settings and clicking Register External.


質問 # 37
A systems administrator is tasked to deploy a management domain during VMware Cloud Foundation Bring-Up process. What are the minimum hardware requirements for the management cluster?

  • A. 2 vSAN Ready Nodes, 192 GB RAM per server, and 4 10GbE NICs
  • B. 8 vSAN Ready Nodes, 256 GB RAM per server, and 2 10GbE NICs
  • C. 6 vSAN Ready Nodes, 256 GB RAM per server, and 4 10GbE NICs
  • D. 4 vSAN Ready Nodes, 192 GB RAM per server, and 2 10GbE NICs

正解:D

解説:
Explanation
The minimum hardware requirements for the management cluster during VMware Cloud Foundation Bring-Up process are:
* 4 vSAN Ready Nodes
* 192 GB RAM per server
* 2 10GbE NICs


質問 # 38
An administrator is tasked with deploying a new VI Workload Domain into an existing VMware Cloud Foundation environment. Which three initial shared storage types are supported? (Choose three.)

  • A. vVols
  • B. vSAN
  • C. NFSv3
  • D. SMB 3.0
  • E. VMFS on iSCSI
  • F. NFSV4.1

正解:B、C、E

解説:
Explanation
This is because according to VMware documentation , these are three initial shared storage types that are supported for deploying a new VI Workload Domain into an existing VCF environment. You can also add other supported storage types after deploying the VI Workload Domain.


質問 # 39
An administrator is tasked with providing additional North-South throughput to the workloads hosted on overlay-backed networks in a VI Workload Domain stretched cluster. A two-node NSX Edge cluster was previously deployed through SDDC Manager before the cluster was stretched.
Which option is valid to add two nodes to the existing edge cluster while maintaining password rotation capability?

  • A. Expand the existing NSX Edge cluster using SDDC Manager, and place the additional NSX Edge nodes on the same stretched Workload Domain cluster.
  • B. Expand the existing NSX Edge cluster using NSX Manager, and import the additional nodes in SDDC Manager.
  • C. Expand the existing NSX Edge cluster using SDDC Manager, and place the additional NSX Edge nodes on a different stretched Workload Domain cluster.
  • D. Create a new NSX Edge cluster using SDDC Manager on the same stretched Workload Domain cluster.

正解:A

解説:
Explanation
According to VMware Cloud Foundation Specialist (v2) Exam , one of the objectives is to "Describe how to expand an existing NSX-T Edge cluster". The exam guide also states that"SDDC Manager provides a single point of management for password rotation" and that "password rotation must be performed through SDDC Manager".


質問 # 40
Which order of steps should an administrator use to replace a failed host in a stretched cluster?

  • A. Decommission the failed host.
    2. Remove the host using cluster APIs.
    3. Add the newly commissioned host to the cluster using cluster APIs. 4 Commission the new host with the correct network.
  • B. 1 Decommission the failed host
    2. Remove the host using cluster APIs.
    3. Commission the new host with the correct network.
    4. Add the newly commissioned host to the cluster using cluster APIs.
  • C. 1 Remove the host using cluster APIs.
    2. Decommission the failed host.
    3. Commission the new host with the correct network.
    4. Add the newly commissioned host to the cluster using cluster APIs.
  • D. Remove the host using cluster APIs
    2. Decommission the failed host.
    3. Add the newly commissioned host to the cluster using cluster APIs.
    4. Commission the new host with the correct network

正解:A

解説:
Explanation
This is because according to VMware documentation1, these are the steps to replace a failed host in a stretched cluster:
* Run the compact cluster API to remove any stale data from vSAN.
* Decommission the host to be removed using SDDC Manager UI or API.
* Commission the replacement host to the same network pool as the removed host using SDDC Manager UI or API.
* Add the newly commissioned host to the cluster using SDDC Manager UI or API.
* Explanation: According to the VMware documentation, when replacing a failed host in a stretched cluster, the first step is to decommission the failed host. This should be followed by removing the host using cluster APIs, commissioning the new host with the correct network, and then adding the newly commissioned host to the cluster using cluster APIs.


質問 # 41
An administrator is tasked with preparing hosts for the deployment of a new Workload Domain in a VMware Cloud Foundation environment.The ESXi hosts have HBA cards that require the installation of a separate and the most recent VMware Installation Bundles (VIBs).
Which ESXi imaging method should the administrator use?

  • A. VMware vSphere Lifecycle Manager Images
  • B. VMware Imaging Appliance
  • C. Download and burn the base ESXi Installer ISO Image to a DVD
  • D. VMware vSphere Auto Deploy

正解:B

解説:
Explanation
This is because according to VMware documentation1, the VMware Imaging Appliance (VIA) is a tool that automates ESXi host imaging and configuration for VCF deployments. It supports custom ESXi images that include additional drivers or VIBs that are not part of the base ESXi image2. You can download ESXi software and VIBs from VMware or third-party sources and upload them to VIA for creating custom images3.


質問 # 42
What is a supported function of the vSphere Lifecycle Manager (LCM) in VMware Cloud Foundation (VCF)?

  • A. Upgrade SDDC Manager
  • B. Downgrade VM hardware version
  • C. Check hardware compatibility of hosts and clusters
  • D. Upgrade vCenter Server

正解:D

解説:
Explanation
The VMware Cloud Foundation Specialist (v2) certification exam guide from VMware specifically mentions that "Upgrade vCenter Server to a new version using vSphere Lifecycle Manager (vLCM)" is a key knowledge area for the exam (source[1][2]:https://www.vmware.com/education-services/certification/vcf-specialist-exam.html).
Additionally, search result [1] mentions that SDDC Manager is responsible for the life cycle management of vCenter Server and other components[3], indicating that vSphere LCM is specifically responsible for upgrading vCenter Server, a supported function.
a supported function of vSphere Lifecycle Manager (LCM) in VMware Cloud Foundation (VCF) is Option A:
Upgrade vCenter Server 1. vSphere Lifecycle Manager provides a framework for desired state lifecycle management of vSphere hosts in a cluster 2.
https://docs.vmware.com/en/VMware-vSphere/8.0/vsphere-lifecycle-manager/GUID-F0635413-D52A-4115-A7


質問 # 43
An administrator needs to upgrade the current VMware Cloud Foundation (VCF) environment from version
4.1 to 4.3, knowing that the environment has direct access to the internet.
Which steps should be performed to download the online bundles?

  • A. 1 SDDC Manager checks depot.vmware com.
    2. The administrator accesses vSphere Lifecycle Manager
    3. The administrator downloads the bundles from vSphere Lifecycle Manager
  • B. 1 vSphere Lifecycle Manager checks depot.vmware.com.
    2. The administrator accesses vSphere Lifecycle Manager.
    3. The administrator downloads the bundles from vSphere Lifecycle Manager.
  • C. 1. vSphere Lifecycle Manager checks depot vmware.com
    2. The administrator accesses SDDC Manager.
    3. The administrator downloads the bundles from SDDC Manager.
  • D. 1. SDDC Manager checks depot.vmware com.
    2. The administrator accesses SDDC Manager.
    3. The administrator downloads the bundles from SDDC Manager.

正解:D

解説:
Explanation
This is because according to VMware documentation , SDDC Manager is responsible for checking and downloading the online bundles for VCF upgrades from depot.vmware.com. The administrator can access SDDC Manager and download the bundles from Inventory > Workload Domains > MGMT > Update/Patches.


質問 # 44
Which service is integrated with VMware Cloud Foundation and enables a centralized and simplified lifecycle management of ESXi host?

  • A. Solutions Manager
  • B. vSphere Lifecycle Manager
  • C. vRealize Suite Lifecycle Manager
  • D. vCenter Lifecycle Manager

正解:B

解説:
Explanation
The service that is integrated with VMware Cloud Foundation and enables a centralized and simplified lifecycle management of ESXi host is Option B: vSphere Lifecycle Manager (vLCM) 1.
vLCM enables you to create cluster images for centralized and simplified lifecycle management of ESXi hosts including firmware. When a VI workload domain cluster is created with an image, you can update and upgrade the ESXi version on all hosts in the cluster collectively vSphere Lifecycle Manager (vLCM) is a key component of VMware Cloud Foundation (VCF) that enables centralized and simplified lifecycle management of ESXi hosts. It provides a single interface to manage host baselines, firmware and driver updates, and upgrades. With vLCM, administrators can create custom images for ESXi hosts, define baselines for host compliance, and apply updates to hosts in a coordinated manner. This helps to ensure consistency across the environment and reduce the risk of configuration drift. (source:
VMware Cloud Foundation 4.x Architecture and Deployment Guide)


質問 # 45
An architect is presented with a Bill of Material for different vSAN ready nodes:
* 8 identical nodes with 1 vSAN disk group
* 8 identical nodes with 2 vSAN disk groups
What is the ideal design of VMware Cloud Foundation domains that the architect should recommend?

  • A. 1 Management Domain of 6 Nodes, 1 Workload Domain of 4 nodes, and 1 Workload Domain of 6 nodes
  • B. 1 Management Domain of 4 nodes, 1 Workload Domain of 4 nodes, and 1 Workload Domain of 8 nodes
  • C. 1 Management Domain of 6 nodes and 1 Workload Domain of 10 nodes
  • D. 1 Domain of 16 nodes deployed on a Consolidated Architecture model

正解:B

解説:
Explanation
This is because according to VMware documentation, this is the ideal design of VMware Cloud Foundation domains that the architect should recommend based on the Bill of Material for different vSAN ready nodes.
This design can provide optimal performance and availability by using vSAN ready nodes with different disk group configurations for different domains based on their workload characteristics and requirements. The management domain can use vSAN ready nodes with one disk group per node to provide sufficient capacity and redundancy for management components such as vCenter Server and NSX Manager. The workload domains can use vSAN ready nodes with two disk groups per node to provide higher performance and throughput for VI workloads such as VMs and containers.


質問 # 46
Which license is required to enable Workload Management on VMware Cloud Foundation?

  • A. VMware Tanzu Basic
  • B. VMware vSphere Standard
  • C. VMware vSphere Enterprise Plus
  • D. VMware vSphere Evaluation

正解:A

解説:
Explanation
A Tanzu Basic license is required to enable Workload Management on VMware Cloud Foundation. Once enabled, the Supervisor Cluster must be assigned a Tanzu license before the 60-day evaluation period expires.
This license can be added to the license inventory of vSphere if a valid Tanzu Edition license is available.


質問 # 47
A systems administrator is tasked with creating a new VI workload domain that will leverage either an external NFS or a VMFS on FC storage as the principal storage.
Which action is required to fulfill this requirement?

  • A. Create a new network pool for vMotion and vSAN networks.
  • B. Create a new network pool for vMotion, vSAN, and NFS networks.
  • C. Create a new network pool only for vMotion network.
  • D. Create a new network pool for vMotion and NFS networks.

正解:D

解説:
Explanation
This is because a network pool is a collection of subnets within an layer-2 network domain that includes information about subnets reserved for the vMotion and NFS networks that are required for adding a host to the SDDC Manager inventory2. The other options are not correct because they either include vSAN network, which is not needed for external NFS or VMFS on FC storage , or they do not include NFS network, which is needed for external NFS storage1
https://infohub.delltechnologies.com/l/dell-storage-with-vmware-cloud-foundation-1/vmware-cloud-foundation-n


質問 # 48
An administrator wants to delete a VMware Cloud Foundation Workload Domain and re-use the attached ESXi hosts by returning them to the list of unassigned hosts in the SDDC Manager inventory.
Which action needs to be taken to complete this task?

  • A. ESXi hosts need to be re-imaged and rejoined.
  • B. ESXi hosts need to be decommissioned and updated
  • C. ESXi hosts need to be re-imaged and updated.
  • D. ESXi hosts need to be decommissioned and re-imaged.

正解:D

解説:
Explanation
This is because according to VMware documentation, this is the procedure for deleting a VMware Cloud Foundation Workload Domain and re-using its ESXi hosts:
* Decommission all ESXi hosts in a cluster
* Delete all clusters in a workload domain
* Delete workload domain
* Re-image ESXi hosts using SDDC Manager


質問 # 49
A VMware Cloud Foundation (VCF) architect is presented with a customer's requirements for an architecture that needs to achieve:
* Network high availability across workloads in two data center locations.
* Maintain the least administrative overhead when performing day 2 operations.
* Decrease the RTO of both management plane and data plane when site-wide failure occurs Which VCF design consideration should the architect recommend?

  • A. VCF with NSX-T Bridging
  • B. VCF with NSX-T Federation
  • C. VCF with NSX-T L2-VPN
  • D. VCF with NSX-T Multi-Site

正解:B

解説:
Explanation
According to VMware Cloud Foundation Architecture Poster, VCF with NSX-T Federation provides network high availability across workloads in two data center locations bysynchronizing network configuration and state across sites. It also simplifies day 2 operations by providing centralized management and policy enforcement across sites. It also reduces RTO by enabling fast failover of network services between sites.


質問 # 50
An administrator wants to scale an existing VMware Cloud Foundation (VCF) environment by adding a new VI Workload Domain. Which two storage options can be used for the new VI Workload Domain? (Choose two.)

  • A. iSCSI principal storage with SMB supplemental storage
  • B. vSAN principal storage with SMB supplemental storage
  • C. vSAN principal storage with NFS supplemental storage
  • D. vVOL principal storage with SCSI supplemental storage
  • E. vSAN principal storage with VMFS on FC supplemental storage

正解:C、E

解説:
Explanation
This is because according to VMware documentation, these are some of the storage options that can be used for a new VI Workload Domain:
* vSAN principal storage with VMFS on FC supplemental storage: You can use vSAN as your primary storage platform and add VMFS on FC as an additional storage option.
* vSAN principal storage with NFS supplemental storage: You can use vSAN as your primary storage platform and add NFS as an additional storage option.


質問 # 51
Which statement is true regarding NSX Manager configuration in a VMware Cloud Foundation environment?

  • A. NSX Managers can be deployed to different VLANs.
  • B. The cluster virtual IP address is attached to all NSX Managers.
  • C. The cluster virtual IP address is used for API and GUI access to NSX Managers.
  • D. Traffic is load-balanced across all NSX Managers while using the virtual IP address.

正解:C

解説:
Explanation
According to VMware Cloud Foundation Planning and Preparation Workbook, a statement that is true regarding NSX Manager configuration in a VMware Cloud Foundation environment is:
* The cluster virtual IP address (VIP) address must be used for API and GUI access to NSX Managers


質問 # 52
......

確認済み5V0-31.22試験問題集と解答で時間限定無料提供!5V0-31.22には正解付き:https://www.jpntest.com/shiken/5V0-31.22-mondaishu

弊社を連絡する

我々は12時間以内ですべてのお問い合わせを答えます。

オンラインサポート時間:( UTC+9 ) 9:00-24:00
月曜日から土曜日まで

サポート:現在連絡